2).BrakeType: Off,Soft brake and Hard brake. default is Off (brake disable). Soft brake: less forceful and brake time is longer. Hard brake: more forceful and brake time is shorter.
3).AdvanceT(Timing Mode): Low, Middle and High, default is Middle. Low advance timing is recommended for high inductance and low KV motors. High advance timing is recommended for low inductance and high KV motors, e.g. high KV outrunner motors. For some high KV motors, if it shakes while rotating in high speed, the “High” timing mode is recommended.
4).Start: Fast, Soft and Very Soft. default is Very Soft. Fast start is recommended for low inductance and low start loading motors, Very Soft start is recommended for high inductance and high start loading motors.
5).OffType(Cutoff Mode,Low Voltage Protection Mode): Reduce power and Cutoff output power for selecting, default is Reduce the output power gradually to 50% of the current power.
6).Freq=: PWM frequency, 13KHz and 8KHz, default is 8KHz.
7).NeutRange : Throttle neuture range, Available in car mode only.
8).Curve(Throttle Curve Mode): Curve1, Curve2 and Curve3. default is Curve1.
9).StPercent (Start power) : to set the Percent of output power when motor start in range of 00% - 39%, default is 00%. Under default setting, output power is decided automatically by system according to throttle stick position.
10).Model: selection for airplane model or car model ,airplane model only for this serial( XP serial ).
11).Reverse(Motor Rotation): Normal and Reverse. default is Normal.
12).CarDir: Car Model Direction type. Available in car model only.